Types of resistors

Braking resistors Braking resistor use inside the vehicle

 trakcyjne wewnatrz

Braking resistor with forced cooling for the use inside the vehicle.

Application

Braking resistors for mounting inside a traction vehicle are used in locomotives and electric trains, and diesel engine locomotive

train loco

 

 

trakcyjne wewnatrz
Przykład konstrukcji rezystora z chłodzeniem wymuszonym stosowanego w pojazdach metra

Design of braking resistors mounted inside the vehicle

Braking resistors mounted inside the vehicle are designs with vertical forced cooling. Braking resistor is made of ribbon resistance elements mounted in a duct through which cooling air flows.  Additionally, the resistor is also equipped with a cooling fan or it is mounted in the enclosure where the cooling air is supplied from the outside [then the fan is not included in the scope of delivery of the resistor by SIMPAX]. Such a resistor usually consists of two resistance modules (in some cases one resistance module), which are connected to the braking chopper.

 

The most important features of the resistor design:

The design resistant to moisture.

Such a resistor is a design with IP20, where active elements of the resistor (being under voltage) are exposed to moisture and pollution. It is made entirely of stainless materials or covered with anti-corrosive layers (The cooling fan frame is galvanized, and the busbars are of copper coated with CuNi).

Vibration resistant design:

The individual connections of the resistor design parts are made with screw connections, which pays special attention to the appropriate selection of the screw connection type and the tightening torques.

This solution guarantees that the connections will not be unscrewed while operating on the vehicle. Additionally, for the prototype resistors, vibration resistance tests are carried out in accordance with the EN-61373 standard

These resistors additionally have welded elements – the frame in which the cooling fan is mounted. These elements are compliant with the EN-15085 standard, Class CP-C2

The design is resistant to high temperatures.

The resistance elements of the resistors warm up during operation up to temperatures around 600°C, which causes their elongation and the possibility of contact with each other and, as a consequence, internal short-circuits of a resistor. Therefore, the design of SIMPAX resistors is made in such a way as to compensate for the thermal expansion of the steel. Resistor enclosures are made of stainless steel resistant to high temperatures.

Its design includes the following aspects:

  • the most efficient air exchange possible, resulting in better cooling of the resistor using resistance elements that cause low resistance to cooling air flow.
  • application of efficient cooling fans compliant with railway standards. Thanks to this, the resistance segment can have smaller dimensions than in case of natural cooling
  • outputting resistor connection terminals to a place where there are no high temperatures

 

Technical parameters of the braking resistor mounted inside a vehicle unit

Number of modules:

Specify

Standard 1 or 2

 

Rated resistance: Rn

Specify

[Ω] +7%/-5% according to EN-60322

Permissible minimum resistance at minimum operating temperature: Rmin

Specify

[Ω] It cannot fall below the value causing a higher braking current than the max. chopper current

Permissible maximum resistance – hot resistor

Specify. Standard Rn + 35% – 40%

[Ω] It cannot rise above the value causing too little braking resistor power

Rated energy released during braking in the worst case scenario 

Specify 

[J]

Rated braking power or rated continuous power

Specify

[kW]

Rated work cycle

Please specify

Typically, a continuous power is given for this type of resistors 

Rated operating voltage Un

Specify

[V] EN-50163

Peak voltage

Specify

[V] Occurs, for example, during emergency braking

Pollution degree

PD4

In accordance with EN-50124-1

Overvoltage category

OV2

In accordance with EN-50124-1

Rated insulation voltage: Unm

Depends on Un

In accordance with EN-50124-1

Impulse voltage: Uni

Depends on Un, PD, OV

In accordance with  EN-50124-1

Insulation test voltage

Depends on Un

In accordance with EN-60322

IP rating:

IP20

For the enclosure and the junction box

Cooling type

Natural

 

Maximum resistor temperature

Standard 600˚C

 

Maximum instantaneous resistor temperature

Standard 800˚C

In emergency situations

Permissible resistor dimensions:

Specify

 

Operating conditions

Ambient temperature

Specify

Standard: -25˚C; 40˚C

Max operating altitude a.s.l.

Specify

Standard < 1000m n.p.m.

Shock and vibration

Cat. 1 / Class A all directions

In accordance with EN-61373

Permissible load of top of the resistor enclosure (the ability to walk on the enclosure)

Specify

Standard 0 kg

No entry on the resistor enclosure

Environment corrosivity category

C5-I

In accordance with ISO12944-2

Other

Maximum temperature of the resistor exhausted air

Standard < 200˚C

 

Sound power level

≤70dB

In accordance with IEC 60076-10 at 1 m distance

 

Types of resistor testing

S – standard, O – option, N – not applicable

Type of test

Type test (for the prototype)

Routine tests (each unit)

Standard

Visual inspection

S

S

EN61287-1

Dimensional verification

S

S

EN 61287-1

Resistor mass verification

S

O

EN 61287-1

Resistor marking verification

S

S

EN 61287-1

Resistor resistance measurement

S

S

EN 60322

Inductance measurement

S

O

EN 60322

Resistor temperature increase measurement (test under load)

O / S

N

EN 60322

Shock and vibration test

O / S

N

EN 61373

Insulation test

S

S

EN 60322

Rain exposure test

O

N

EN 60322

Other types of tests on request

O

O

 

Applied Standards:

  • EN-60322:2011 / Railway applications - Electric equipment for rolling stock - Rules for power resistors of open construction
  • EN-50124-1:2006 / Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
  • EN-61373:2011 / Railway applications - Rolling Stock Equipment - Shock And Vibration Tests
  • EN-60077:2018 / Railway applications - Electric equipment for rolling stock - Part 1: General service conditions and general rules
  • EN-60529:2003 / Degrees of protection provided by enclosures (IP code)

 

SIMPAX sp. z o.o.

Grabonóg 76
63-820 Piaski
(k. Gostynia)

+48 65 571 20 60
info@simpax.pl

a j